Grand opening, up to 15% off all items. Only 3 days left
  • The First Online Medical And Healthcare Market
  • hotline

    01004681355 24/7 Support Center

    In Stock

    AKAIMED Patient Monitor (ACCU1200 plus) Display TFT 12'' 7 functions For Adult, Pediatric, Neonate Trend 240 hr Including built in rechargeable battery & thermal printer (Black)

    (32 reviews)
    77917 EGP
    • Brand: AKAIMED
    • Country Origin: Hong Kong
    • words.stock: 100 Item In Stock

    Patient Monitor (ACCU1200 plus) Display TFT 12''- 7 functions- For Adult, Pediatric, Neonate- Trend 240 hr - Including built in rechargeable battery & thermal printer (Black) - by AKAIMED Display: Size: 12.1 inch color TFT Resolution: 800 x 600 pixels Indicators: Categorized alarms (3 priority levels) Visible and audible alarm Battery Power Indicator Battery: 2.5 hours rechargeable Li-ion battery Trend Time: 240 hr Recorder: Thermal array (Up to 3 channels) Data Transfer: USB OTG port .SD cart slot and USB port ACCU-1200 Parameters: ACCU-1200 Plus Parameters: Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, CO2, IBP ECG: Lead Mode 3-Lead: I, II, III 5-Lead: I, II, III, aVR, aVL, aVF, V Waveform 3-Lead: 1-channel waveform 5-Lead: 2-channel waveform, max. 7 waveforms; Waveform Speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s Heart rate: Measurement Range ADU: 15 bpm ~ 300 bpm PED: 15 bpm ~ 350 bpm Accuracy ±1% or ±1 bpm, whichever is greater Resolution 1 bpm ST segment analysis: Measurement Range: -2.0 mV ~ +2.0 mV Arrhythmia analysis 16 different arrhythmia analysis classification (applicable to adult and pediatric) SPO2: Measurement Range 0 ~ 100 % Accuracy ±2 % (70%~100% SpO2) Undefined (0~69% SpO2) Pulse Rate Range 20bpm ~ 300bpm Pulse Rate Accuracy ±3bpm Respiration: Measurement method: Trans-thoracic impedance RR measuring range: Adult 0 to 120 rpm Pediatric 0 to 150 rpm Apnea Alarm: Yes NIBP: Measurement Method: Oscillometric Operation mode: Manual/Automatic/Continuous Cuff pressure measuring range: 0 mmHg ~ 300 mmHg Measurement Range: Adult mode SYS: 40 mmHg ~ 270 mmHg DIA: 10 mmHg ~ 215 mmHg MAP: 20 mmHg ~ 235 mmHg Pediatric mode SYS: 40 mmHg ~ 200 mmHg DIA: 10 mmHg ~ 150 mmHg MAP: 20 mmHg ~ 165 mmHg TEMP: Measurement method: Thermal resistance Channel: 2 Measuring Range: 0.0 °C ~ 50.0 °C Resolution: 0.1°C Accuracy (Without sensor): +/-0.1°C CO2: (Standard only Accu1200 Plus) Measurement method Infra-red Absorption Technique CO2 Measuring Range 0~ 20% (0 mmHg ~ 150 mmHg) CO2 Measuring Accuracy < 5.0% CO2: ± 2 mmHg > 5.0% CO2: < 6% of the readings

    Customer questions & answers

    December 4, 2022 at 3:12 pm

    Lorem ipsum dolor sit amet, consectetur adipisicing elit. Delectus, suscipit exercitationem accusantium obcaecati quos voluptate nesciunt facilis itaque modi commodi dignissimos sequi repudiandae minus ab deleniti totam officia id incidunt? Reply

    December 4, 2022 at 3:12 pm

    Lorem ipsum dolor sit amet, consectetur adipisicing elit. Delectus, suscipit exercitationem accusantium obcaecati quos voluptate nesciunt facilis itaque modi commodi dignissimos sequi repudiandae minus ab deleniti totam officia id incidunt? Reply

    December 4, 2022 at 3:12 pm

    Lorem ipsum dolor sit amet, consectetur adipisicing elit. Delectus, suscipit exercitationem accusantium obcaecati quos voluptate nesciunt facilis itaque modi commodi dignissimos sequi repudiandae minus ab deleniti totam officia id incidunt? Reply

    Customer reviews

    4.8 out of 5
    5 star
    50%
    4 star
    25%
    3 star
    45%
    2 star
    65%
    1 star
    85%
    How are ratings calculated?

    Add a review