Advanced Vital Signs Monitor RVS 100 - by Riester
Product Details:
- 3 measurement modes (Monitor, Spot-check, Triage).
- High-sensitivity 8” TFT colour touch screen with self-explanatory user interface and integrated help function.
- Displays SYS, DIA, MAP, Pulse, Temp, Plethysmogram.
- Clinical grade NIBP* including averaging mode.
- Programmable NIBP averaging mode (2-5 readings).
- Riester, Masimo* or Nellcor* Oximax SpO2.
- Predictive Thermometer (Filac 3000).
- Connectivity with the EMR - follows the HL7 standard.
- LAN Connectivity as standard.
- Programmable alarms (audible, visible) with 3 priority levels.
- Supports nurse call RJ11 port.
- Available as wall, desk and floor model.
- Can be expanded to wall diagnostic station.
- Internal memory for 5,000 measurements.
- Lithium-ion battery with up to 17 hours ON time (*includes neonate mode).
Options:
- Thermal printer (internal)
- Barcode reader
- Mobile stand including basket for storage (cuffs, sensors, cables) - WiFi - Accessories supplied with monitor - NIBP extension tube - 2 cuffs (adult & adult large incl. connectors) - SpO2 sensor adult - SpO2 extension cable - Oral temperature probe - Probe cover Technical Data: Monitor Power Supply: 100 – 240 V AC, 50/60 Hz Battery: Lithium-Ion battery, rechargeable, 10.8 V DC, 6,600 mAh, Charging time to a 100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery at 25°C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval)) Low battery indicator Charging battery indicator Dimensions Monitor: L x H x W: 303 x 230 x 110 mm (11.93 x 9.06 x 4.33 in) Weight: 3.60 kg (7.94 lb) including temp module, printer Dimensions Basket: L x H x W: 270 x 225 x 200 mm (10.63 x 8.86 x 7.88 in) Alarm: Visible LEDs (Yellow, Red, Blue, Green, Orange) Audible Speaker Gives audible alarm, QRS tone Supports Pitch Tone and multi-level volume Alarm tones meet the requirement of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone. Ports: 1 x AC power inlet 1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3 4 x USB ports 1 x Equipotential grounding point 1 x RJ11 connector for nurse call DC out port 15V/1.2 A Clinical-grade NIBP (non-invasive blood pressure) Clinical-grade NIBP (non-invasive blood pressure) Measuring method: automatic oscillometric Measurement range: Adult SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg Pediatric SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg Neonate SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg Cuff pressure range: 0 – 280 mmHg Resolution: 1 mmHg Pressure accuracy: Static ±3 mmHg Clinic ±5 mmHg, standard deviation ≤ 8 mmHg Pulse rate range: 40 – 240 bpm Pulse rate accuracy: 1 bpm Initial inflation pressure: Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg Double overpressure protection (hardware and software) Adult 297 ± 3 mmHg, Pediatric 252 ± 3 mmHg , Neonate 147 ± 3 mmHg Alarm range: SYS 0 – 300 mmHg DIA 0 – 300 mmHg MAP 0 – 300 mmHg Riester SpO2 Measurement range: 0 – 100% Resolution: 1% Accuracy: ±2% (70 to 100%) ±3% (40% to 69%) Unspecified (0% to 39%) Alarm range: 0 – 100% Average time: 4 sec, 8 sec, 16 sec Pulse rate: Measurement range: 20 – 250 bpm Resolution: 1 bpm Accuracy: ±1% or ±1 bpm whichever is greater Nellcor SpO2 Measurement range: 0-100% Resolution: 1% Accuracy: 70 – 100%: ±2% (adult, pediatric) 70 – 100%: ±3% (neonate) Unspecified (0 – 69%) Alarm range: 0 – 100% Average time: 8 sec, 16 sec Pulse rate: Measurement range: 20 – 300 bpm Resolution: 1 bpm Accuracy: 20 – 250 bpm: ±3 bpm 251 – 300 bpm: unspecified Masimo SpO2: Measurement range: 0 – 100% Resolution: 1% Accuracy: 70 – 100%: ±2% (adult, pediatric, non-motion conditions) 70 – 100%: ±3% (neonate, non-motion conditions) 70 – 100%: ±3% (motion conditions) 0 – 69%: unspecified Average time: 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec Pulse rate: Measurement range: 25 – 240 bpm Resolution: 1 bpm Accuracy: ±3 bpm (non-motion conditions) ±5 bpm (motion conditions) Predictive thermometer: Oral ( Quick Mode ) non-fever temps: 3-5 seconds fever temps: 8-10 seconds Oral ( Standard Mode ): 6-10 seconds Axillary Mode: 8-12 seconds Rectal Mode: 10-14 seconds Direct Mode (all sites): 60-120 seconds Measurement accuracy: 35.5ºC - 42ºC (95.9°F – 107.6°F) Direct Mode (all sites): ±0.1ºC (±0.2ºF) Standard Prediction Mode (all sites): ±0.1ºC (±0.2ºF) Quick Prediction Mode (oral only): ±0.3ºC (±0.5ºF)
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Delectus, suscipit exercitationem accusantium obcaecati quos voluptate nesciunt facilis itaque modi commodi dignissimos sequi repudiandae minus ab deleniti totam officia id incidunt? Reply
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Delectus, suscipit exercitationem accusantium obcaecati quos voluptate nesciunt facilis itaque modi commodi dignissimos sequi repudiandae minus ab deleniti totam officia id incidunt? Reply
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Delectus, suscipit exercitationem accusantium obcaecati quos voluptate nesciunt facilis itaque modi commodi dignissimos sequi repudiandae minus ab deleniti totam officia id incidunt? Reply